• DocumentCode
    2452197
  • Title

    Sensor for high-air-humidity measurement

  • Author

    Matko, V. ; Donlagic, D.

  • fYear
    1996
  • fDate
    17-21 June 1996
  • Firstpage
    351
  • Lastpage
    353
  • Abstract
    The humidity sensor using the sensitive capacitive-dependent crystal is described. Presented is the probe sensitivity (dependence of df on the dCx). In addition the new idea of excitation of the entire humidity sensor with stochastic test signals is described, and the humidity surface-measuring method is given. It includes the influence of test signals of the weighting function uncertainty and of the A/D-D/A conversion. The results of humidity measurement with the excitation signals are shown experimentally. The uncertainty of the surface humidity measurement is less than 0.2% (T=15 to 25/spl deg/C and humidity=50 to 98%).
  • Keywords
    analogue-digital conversion; capacitance measurement; digital-analogue conversion; electric sensing devices; humidity measurement; A/D-D/A conversion; excitation signals; high-air-humidity measurement; humidity sensor; humidity surface-measuring method; probe sensitivity; sensitive capacitive-dependent crystal; stochastic test signals; test signals; weighting function uncertainty; Capacitance measurement; Capacitive sensors; Equations; Frequency; Humidity measurement; Oscillators; Probes; Pulse width modulation; Stability; Temperature sensors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1996 Conference on
  • Conference_Location
    Braunschweig, Germany
  • Print_ISBN
    0-7803-3376-4
  • Type

    conf

  • DOI
    10.1109/CPEM.1996.547110
  • Filename
    547110