DocumentCode :
2452912
Title :
Absolute determination of loss angle
Author :
Eklund, G.
Author_Institution :
Swedish Nat. Testing & Res. Inst., Boras, Sweden
fYear :
1996
fDate :
17-21 June 1996
Firstpage :
390
Lastpage :
391
Abstract :
A guard ring capacitor has been constructed and is used for absolute determinations of the loss angle of capacitors at SP (Swedish National Testing and Research Institute). The accuracy is estimated to /spl plusmn/1 ppm (k=2). The main source of error is from the quadrature errors in the capacitance bridge.
Keywords :
bridge circuits; bridge instruments; capacitors; dielectric loss measurement; electron device testing; loss-angle measurement; measurement errors; 20 to 100 pF; Swedish National Testing and Research Institute; accuracy; capacitance bridge; capacitor loss angle; guard ring capacitor; loss angle measurement; quadrature errors; Bridge circuits; Capacitance; Capacitors; Dielectric losses; Electrodes; Equations; Loss measurement; Resistors; Surface resistance; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements Digest, 1996 Conference on
Conference_Location :
Braunschweig, Germany
Print_ISBN :
0-7803-3376-4
Type :
conf
DOI :
10.1109/CPEM.1996.547129
Filename :
547129
Link To Document :
بازگشت