DocumentCode :
2453118
Title :
Calibration of the standard resistors by means of the standard capacitors and precise digital voltmeters
Author :
Bego, V. ; Butorac, J. ; Hrsan, D.
Author_Institution :
Fac. of Electr. Eng. & Comput., Zagreb Univ., Croatia
fYear :
1996
fDate :
17-21 June 1996
Firstpage :
392
Lastpage :
393
Abstract :
The calibration is carried out by measuring the ratios of voltages on an auxiliary resistor, once as a result of the current flowing through the previously calibrated capacitance standard, and the other time as a result of the current through the resistance standard. Using these voltage ratios, obtained with DC and low frequency AC current, measured by the precise digital voltmeters, a resistance standard can be calibrated with the uncertainty of 0.2 ppm.
Keywords :
calibration; capacitance measurement; digital voltmeters; electric resistance measurement; measurement standards; resistors; voltmeters; DC current; auxiliary resistor; capacitance standard; digital voltmeters; low frequency AC current; resistance standard; standard capacitors; standard resistor calibration; uncertainty; voltage ratio measurement; Calibration; Capacitance measurement; Current measurement; Electrical resistance measurement; Frequency measurement; Measurement standards; Resistors; Time measurement; Voltage; Voltmeters;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements Digest, 1996 Conference on
Conference_Location :
Braunschweig, Germany
Print_ISBN :
0-7803-3376-4
Type :
conf
DOI :
10.1109/CPEM.1996.547130
Filename :
547130
Link To Document :
بازگشت