• DocumentCode
    2453118
  • Title

    Calibration of the standard resistors by means of the standard capacitors and precise digital voltmeters

  • Author

    Bego, V. ; Butorac, J. ; Hrsan, D.

  • Author_Institution
    Fac. of Electr. Eng. & Comput., Zagreb Univ., Croatia
  • fYear
    1996
  • fDate
    17-21 June 1996
  • Firstpage
    392
  • Lastpage
    393
  • Abstract
    The calibration is carried out by measuring the ratios of voltages on an auxiliary resistor, once as a result of the current flowing through the previously calibrated capacitance standard, and the other time as a result of the current through the resistance standard. Using these voltage ratios, obtained with DC and low frequency AC current, measured by the precise digital voltmeters, a resistance standard can be calibrated with the uncertainty of 0.2 ppm.
  • Keywords
    calibration; capacitance measurement; digital voltmeters; electric resistance measurement; measurement standards; resistors; voltmeters; DC current; auxiliary resistor; capacitance standard; digital voltmeters; low frequency AC current; resistance standard; standard capacitors; standard resistor calibration; uncertainty; voltage ratio measurement; Calibration; Capacitance measurement; Current measurement; Electrical resistance measurement; Frequency measurement; Measurement standards; Resistors; Time measurement; Voltage; Voltmeters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1996 Conference on
  • Conference_Location
    Braunschweig, Germany
  • Print_ISBN
    0-7803-3376-4
  • Type

    conf

  • DOI
    10.1109/CPEM.1996.547130
  • Filename
    547130