Experiment study on preventing and extinguishing fire using stopping agent
Author :
Sun, Chengkun ; Yao, Jian ; Tian, Dongmei
Author_Institution :
Fac. of Recourses & Safety Eng., China Univ. of Min. & Technol., Beijing, China
fYear :
2011
fDate :
24-26 June 2011
Firstpage :
4035
Lastpage :
4037
Abstract :
In order to solve the problem of low efficiency for preventing and extinguishing fire, the principle of preventing and extinguishing fire using stopping agent was analyzed. Affusing liquid system for Coal seam was founded in the scene through selecting many stopping agents to experiment. The result showed Na2CO3 which concentration is 10 percent was the better reasonable as stopping agent of preventing and extinguishing fire for coal seam. It have good effect with checkout in the scene. This result provide science basis for preventing and extinguishing fire.
Keywords :
coal; flameproofing; Na2CO3; coal seam; fire extinguish; fire prevention; liquid system; stopping agent; Coal; Coal mining; Combustion; Educational institutions; Electronic mail; Fires; coal seam affusing water; fire; preventing and extinguishing fire; stopping agent;
fLanguage :