DocumentCode
2459964
Title
RF-DC differences of micropotentiometers
Author
De-Xiang Huang ; Rebuldela, G. ; Harper, J.
Author_Institution
Ballantine Lab. Inc., Cedar Knolls, NJ, USA
fYear
1996
fDate
17-21 June 1996
Firstpage
460
Lastpage
461
Abstract
Various sources of RF-DC differences of a micropotentiometer (/spl mu/pot) are analyzed and calculated, and the results agree well with the experiments. New design reduces the RF-DC differences of /spl mu/pot significantly. Observations show good stability over a 20-year period, which makes /spl mu/pots suitable as primary RF standards in the microvolt and millivolt ranges.
Keywords
measurement errors; measurement standards; potentiometers; stability; voltage measurement; RF-DC differences; micropotentiometers; microvolt range; millivolt range; primary RF standards; stability; Current measurement; Difference equations; Impedance; Inductance; Radio frequency; Resistance heating; Resistors; Skin effect; Tellurium; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 1996 Conference on
Conference_Location
Braunschweig, Germany
Print_ISBN
0-7803-3376-4
Type
conf
DOI
10.1109/CPEM.1996.547165
Filename
547165