• DocumentCode
    2461633
  • Title

    CCE comparison of ac-dc voltage transfer standards at lowest level of uncertainty

  • Author

    Klonz, M.

  • Author_Institution
    Physikalisch Tech. Bundesanstalt, Braunschweig, Germany
  • fYear
    1996
  • fDate
    17-21 June 1996
  • Firstpage
    491
  • Lastpage
    492
  • Abstract
    In May 1996 the international comparison of ac-dc voltage transfer standards at lowest level of uncertainty, using a multijunction thermal converter as the travelling standard, will be completed. Intermediate results show an agreement of the majority of the participating laboratories of better than 0, 4 ppm at the frequency of 1 kHz, 1 ppm at 20 kHz, 1, 8 ppm at 100 kHz and 16 ppm at 1 MHz.
  • Keywords
    measurement errors; measurement standards; voltage measurement; voltage-frequency convertors; 1 MHz; 1 kHz; 100 kHz; 20 kHz; CCE comparison; May 1996; ac-dc voltage transfer standards; participating laboratories; travelling standard; uncertainty; Analog-digital conversion; Frequency; Laboratories; Large-scale systems; Manufacturing; Particle measurements; Testing; Thermal resistance; Uncertainty; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1996 Conference on
  • Conference_Location
    Braunschweig, Germany
  • Print_ISBN
    0-7803-3376-4
  • Type

    conf

  • DOI
    10.1109/CPEM.1996.547181
  • Filename
    547181