• DocumentCode
    2468703
  • Title

    Live working on vintage 138 kV steel lattice structures

  • Author

    Gela, G. ; Fox, H.J. ; Ferraro, R. ; Verdecchio, T. ; Lyons, P.

  • Author_Institution
    EPRI Power Delivery Center, J.A. Jones Power Delivery Inc., Lenox, MA, USA
  • fYear
    1998
  • fDate
    26-30 April 1998
  • Firstpage
    27
  • Lastpage
    32
  • Abstract
    Live working on very old structures often poses unique challenges, such as dealing with the effects of arc rings and the behavior of old insulators. This paper presents the results of tests conducted for Public Service Electric and Gas (USA) to confirm that very old broken insulators can be replaced live on 138 kV double-circuit steel lattice structures with suspension I-strings. Each string had nine porcelain units and two large arc rings with a clear air ring-to-ring distance of 1.07 m (42"). Issues addressed in this paper include: the effects of broken and shorted insulators; the effects of live working tools and workers; and the possibility of selective barehanding. For the above-listed conditions, switching impulse tests were performed on a full-scale mockup of the structure. Actual hardware retrieved from service was used for the mockups. Workers were represented by mannequins. The paper gives switching impulse test results for the outlined conditions. Test data suggest that there is little difference between broken and shorted insulators in the tested cases. However, the CIGRE formula for calculation of the effects of defective insulators is shown to be sufficiently conservative.
  • Keywords
    insulators; maintenance engineering; poles and towers; power overhead lines; 1.07 m; 138 kV; 42 in; arc rings; broken insulator replacement; broken insulators; clear air ring-to-ring distance; defective insulators; double-circuit steel lattice structures; live line working; live working tools; old structures; overhead power line maintenance; porcelain units; selective barehanding; shorted insulators; suspension I-strings; switching impulse tests; Dielectrics and electrical insulation; Gas insulation; Impulse testing; Insulator testing; Lattices; Performance evaluation; Porcelain; Steel; Stress; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Transmission & Distribution Construction, Operation & Live-Line Maintenance Proceedings, 1998. ESMO '98. 1998 IEEE 8th International Conference on
  • Conference_Location
    Orlando, FL, USA
  • Print_ISBN
    0-7803-4883-4
  • Type

    conf

  • DOI
    10.1109/TDCLLM.1998.668327
  • Filename
    668327