DocumentCode :
2468739
Title :
Fourier analysis on critical damp resistance in transient process of RLC series circuit
Author :
Wang, Zongchi ; Liu, Shaowei
Author_Institution :
Department of Physics and Electromechanical Engineerig, Sanming University, Fujian, 365004, China
fYear :
2011
fDate :
24-26 June 2011
Firstpage :
5991
Lastpage :
5994
Abstract :
The reason of deviation between theoretical critical damp resistance and experimental one is analyzed. The critical damp current is expanded Fourier integral of continuous frequency spectrum by Fourier transform, the Fourier integral of critical damping current are separated the Fourier polynomial of finite harmonics of discrete frequency by sampling. The loss resistance of inductor and capacitor are measured when the first harmonic and the harmonics which replace the critical damp current are applied to the RLC series circuit, the experimental value of critical damp resistance is amended, so as to the agreement between the amended experimental value of critical damp resistance and the theoretical one can be obtained.
Keywords :
Electrical resistance measurement; Harmonic analysis; Loss measurement; Physics; RLC circuits; Resistance; Transient analysis; Fourier analysis; critical damp resistance; loss resistance; transient process;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Remote Sensing, Environment and Transportation Engineering (RSETE), 2011 International Conference on
Conference_Location :
Nanjing, China
Print_ISBN :
978-1-4244-9172-8
Type :
conf
DOI :
10.1109/RSETE.2011.5965720
Filename :
5965720
Link To Document :
بازگشت