• DocumentCode
    2469958
  • Title

    3B-1 Noninvasive Insulin Delivery in Large Pigs (> 100 lbs) Using the Lightweight Cymbal Array

  • Author

    Park, Eun-Joo ; Werner, Jacob ; Smith, Nadine Barrie

  • Author_Institution
    Pennsylvania State Univ., University Park
  • fYear
    2007
  • fDate
    28-31 Oct. 2007
  • Firstpage
    104
  • Lastpage
    107
  • Abstract
    Use of needles for multiple injections of drugs, such as insulin for diabetes, can be painful. As a result, prescribed drug noncompliance can results in severe medical complications. In previous studies, ultrasound mediated transdermal drug delivery has shown a promising potential as a method for noninvasive drug administration. Yet for prospective human application, a milestone to a practical clinical device of this research requires that the efficacy of the cymbal array be demonstrated on animals larger than rats and rabbits. Larger and possessing a blood volume similar to humans, pig is an appropriate animal model for further experimentation in evaluating the practicability of this ultrasound device. Six Yorkshire pigs (100-140 lbs) were divided into two groups. As the control (n = 3), the first group did not receive any ultrasound exposure with the insulin. The second group (n = 3) was treated with ultrasound and insulin at 20 kHz with an Isptp = 100 mW/cm2 at a 20% duty cycle for 60 minutes. With the pigs in lateral recumbency after anesthesia, the ultrasound transducer with insulin was placed on the axillary area of the pig. At the beginning and every 15 minutes up to 90 minutes, the blood glucose level was determined using a glucose monitoring system. To compare the results of individual animals, the change of blood glucose level was normalized to each animal´s initial glucose value at the start of the experiment. Although each animal had a different initial glucose level, the mean and standard error for the six animals was 146plusmn13 mg/dl (Figure 1). For the control group, the blood glucose level increased to 31plusmn21 mg/dl compared to the initial baseline over the 90 minute experiment. However for the ultrasound with insulin treated group, the glucose level decreased to -72plusmn5 mg/dl at 60 minutes (p < 0.05) and continued to decreased to -91plusmn23 mg/dl in 90 minutes (p < 0.05). Results demonstrate a promising pre-cli- nical outcome for the low profile cymbal array to be used for ultrasound enhanced in vivo insulin transport using an animal with a similar size and weight to a human. The cymbal array has potential as a practical ultrasound system for noninvasive transdermal insulin delivery for diabetes management.
  • Keywords
    biomedical ultrasonics; blood; drug delivery systems; molecular biophysics; ultrasonic transducers; Yorkshire pigs; diabetes management; lightweight cymbal array; noninvasive drug administration; noninvasive insulin delivery; ultrasound mediated transdermal drug delivery; ultrasound transducer; Animals; Blood; Diabetes; Drugs; Humans; Insulin; Needles; Optical arrays; Sugar; Ultrasonic imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 2007. IEEE
  • Conference_Location
    New York, NY
  • ISSN
    1051-0117
  • Print_ISBN
    978-1-4244-1384-3
  • Electronic_ISBN
    1051-0117
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2007.39
  • Filename
    4409612