• DocumentCode
    2470413
  • Title

    Three level Space Vector Pulse Width Modulation without even order harmonics fit for asymmetrical uniform sampling

  • Author

    Yin, Zhenggang ; Tan, Kai ; Liu, Congwei ; Li, Yaohua

  • Author_Institution
    Inst. of Electr. Eng., Chinese Acad. of Sci., Beijing, China
  • fYear
    2010
  • fDate
    14-17 March 2010
  • Firstpage
    844
  • Lastpage
    849
  • Abstract
    For three level Space Vector Pulse Width Modulation (SVPWM), it is important to make sure that the phase voltage will not change by two levels in one time. It is found out that some even order harmonic elimination PWM method may cause the phase voltage to jump by two steps when asymmetrical uniform sampling technique is used. The condition when two-level voltage jump happens is found out. A new three level SVPWM containing no even order harmonics suitable for asymmetrical sampling is provided. Both simulation and experiment of the new SVPWM show that no two-level voltage jump happens and the even harmonics are eliminated.
  • Keywords
    PWM invertors; harmonics suppression; asymmetrical uniform sampling; order harmonic elimination PWM method; space vector pulse width modulation; Leg; Low voltage; Pulse width modulation converters; Pulse width modulation inverters; Rectifiers; Sampling methods; Space vector pulse width modulation; Switches; Switching frequency; Topology;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Technology (ICIT), 2010 IEEE International Conference on
  • Conference_Location
    Vi a del Mar
  • Print_ISBN
    978-1-4244-5695-6
  • Electronic_ISBN
    978-1-4244-5696-3
  • Type

    conf

  • DOI
    10.1109/ICIT.2010.5472599
  • Filename
    5472599