DocumentCode
2472588
Title
Influence of the surroundings and mainly of the soil on MV cable systems
Author
Burceanu, Monica ; Hennuy, Blandine ; De Clerck, Q. ; Grandjean, Henri ; van den Berg, Martin ; Daems, Kevin ; Leemans, Pieter
Author_Institution
Laborelec, Linkebeek, Belgium
fYear
213
fDate
10-13 June 213
Firstpage
1
Lastpage
4
Abstract
The increase of the load of some Medium Voltage (MV) cables, due to, amongst other things, the development of decentralized production, brings up “new” issues. A practical case of failure in Belgian MV cable networks, highlighted the importance of the thermal characteristics of the soil around highly loaded cables. An analysis of the thermal physical parameters of three types of soil (backfill, sandy and “local soil” type) used around the Belgian cable networks was performed. In order to assure good heat evacuation during the life time of the cable, the characteristics of the soil around loaded MV cables, especially if a “local soil” is used, have to be defined by a set of parameters and not only by the thermal resistivity.
Keywords
power cables; soil; thermal conductivity; Belgian MV cable networks; MV cable systems; backfill type; decentralized production; heat evacuation; loaded cables; local soil type; medium voltage cable systems; sandy type; thermal characteristics; thermal physical parameters; thermal resistivity;
fLanguage
English
Publisher
iet
Conference_Titel
Electricity Distribution (CIRED 2013), 22nd International Conference and Exhibition on
Conference_Location
Stockholm
Electronic_ISBN
978-1-84919-732-8
Type
conf
DOI
10.1049/cp.2013.0858