DocumentCode
2473462
Title
Voltage-current phase angle measurements during aging tests of polymer insulators
Author
Que, Weiguo ; Casale, Edgar P. ; Sebo, Stephen A.
Author_Institution
Dept. of Electr. Eng., Ohio State Univ., Columbus, OH, USA
fYear
2002
fDate
2002
Firstpage
367
Lastpage
370
Abstract
An accurate method for the measurement of the voltage-current phase angle is implemented in a data acquisition system during aging tests of polymer insulators. The voltage-current phase angle and surface resistance measurement results in the course of aging tests are presented and analyzed. The test results show the trends of the phase angle and surface resistance changes during "fog off\´ and "fog on" periods of fog chamber tests.
Keywords
ageing; insulator testing; polymer insulators; surface resistance; aging test; data acquisition system; fog chamber test; outdoor insulation; polymer insulator; surface resistance measurement; voltage-current phase angle measurement; Aging; Data acquisition; Electrical resistance measurement; Goniometers; Insulator testing; Phase measurement; Plastic insulation; Polymers; Surface resistance; Voltage;