• DocumentCode
    2473462
  • Title

    Voltage-current phase angle measurements during aging tests of polymer insulators

  • Author

    Que, Weiguo ; Casale, Edgar P. ; Sebo, Stephen A.

  • Author_Institution
    Dept. of Electr. Eng., Ohio State Univ., Columbus, OH, USA
  • fYear
    2002
  • fDate
    2002
  • Firstpage
    367
  • Lastpage
    370
  • Abstract
    An accurate method for the measurement of the voltage-current phase angle is implemented in a data acquisition system during aging tests of polymer insulators. The voltage-current phase angle and surface resistance measurement results in the course of aging tests are presented and analyzed. The test results show the trends of the phase angle and surface resistance changes during "fog off\´ and "fog on" periods of fog chamber tests.
  • Keywords
    ageing; insulator testing; polymer insulators; surface resistance; aging test; data acquisition system; fog chamber test; outdoor insulation; polymer insulator; surface resistance measurement; voltage-current phase angle measurement; Aging; Data acquisition; Electrical resistance measurement; Goniometers; Insulator testing; Phase measurement; Plastic insulation; Polymers; Surface resistance; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena, 2002 Annual Report Conference on
  • Print_ISBN
    0-7803-7502-5
  • Type

    conf

  • DOI
    10.1109/CEIDP.2002.1048811
  • Filename
    1048811