• DocumentCode
    2473725
  • Title

    Study on the aging of stator insulation in large generators based on dynamic mechanical analysis

  • Author

    Hao, Yanpeng ; Jia, Zhidong ; Zeng, Zheng ; Wang, Guoli ; Gao, Naikui ; Xie, Hengkun

  • Author_Institution
    State Key Lab. of Electr. Insulation for Power Equip., Xi´´an Jiaotong Univ., China
  • fYear
    2002
  • fDate
    2002
  • Firstpage
    404
  • Lastpage
    407
  • Abstract
    Using dynamic mechanical analysis (DMA) technique, the aging of stator insulation in two generators (300 MW, 18 kV) after 18 year and 23 year periods of operation respectively was investigated. The 8 temperature spectra of DMA were measured. According to the typical temperature spectra, several parameters of DMA were calculated. The results show that the parameters might be used to characterize the aging of stator insulation in large generators.
  • Keywords
    ageing; dynamic testing; power transformer insulation; stators; 18 kV; 18 year; 23 year; 300 MW; aging; dynamic mechanical analysis; large generators; stator insulation; temperature spectra; Aging; Capacitive sensors; Dielectric losses; Dielectrics and electrical insulation; Equations; Mechanical variables measurement; Stators; Stress measurement; Temperature; Thermal stresses;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena, 2002 Annual Report Conference on
  • Print_ISBN
    0-7803-7502-5
  • Type

    conf

  • DOI
    10.1109/CEIDP.2002.1048820
  • Filename
    1048820