• DocumentCode
    2474024
  • Title

    Experience with partial discharge, dissipation factor and recovery voltage measurements for the evaluation of insulation systems of high voltage rotating machines

  • Author

    Farahani, M. ; Borsi, H. ; Gockenbach, E.

  • Author_Institution
    Div. of High Voltage Eng. (Schering-Inst.), Hannover Univ., Germany
  • fYear
    2002
  • fDate
    2002
  • Firstpage
    454
  • Lastpage
    457
  • Abstract
    Possibilities and limitations of partial discharge (PD), recovery voltage (RV) and dissipation factor measurement for evaluation of the actual status of insulation systems of high voltage rotating machines are presented. An accelerated cycling thermal ageing procedure was applied on a model insulation system similar to a real machine insulation system and during the ageing procedure the development of the recovery voltage phenomena, partial discharge activities and dielectric dissipation was investigated.
  • Keywords
    ageing; dielectric loss measurement; electric machines; epoxy insulation; insulation testing; machine insulation; partial discharge measurement; stators; voltage measurement; accelerated cycling procedure; dielectric dissipation factor measurement; epoxy VPI technology; high voltage rotating machines; insulation system; model stator bars; partial discharge measurement; recovery voltage measurement; sensitivity; stator winding insulation; test voltage levels; thermal ageing process; Aging; Circuits; Dielectric measurements; Dielectrics and electrical insulation; Partial discharge measurement; Partial discharges; Polarization; Rotating machines; Rotation measurement; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena, 2002 Annual Report Conference on
  • Print_ISBN
    0-7803-7502-5
  • Type

    conf

  • DOI
    10.1109/CEIDP.2002.1048832
  • Filename
    1048832