DocumentCode :
2474194
Title :
Laboratory studies of slot discharges on stator bars
Author :
Lamarre, L. ; Jean, D. ; Nguyen, Duc Ngoc
Author_Institution :
IREQ, Varennes, Que., Canada
fYear :
2002
fDate :
2002
Firstpage :
490
Lastpage :
494
Abstract :
This paper is about experiments carried out on a laboratory stator mock-up comprising 6 stator bars installed in 3 different slots; some of the bars were intentionally damaged in order to reproduce slot discharges. Phase resolved partial discharge (PRPD) patterns, accompanied by simultaneous measurement of capacitance, loss tangent (tan δ) and harmonic analysis were recorded as a function of increasing voltage, from 0 to 16 kV, at steps of 500 V. Another set of results was taken after performing a repair procedure that consists in injecting s/c paint in the stator slots. Results presented here show how slot discharges affect capacitance, tan δ, Qmax, harmonics and PRPD patterns and how all of these quantities are further modified after the injection of s/c paint.
Keywords :
capacitance; harmonic analysis; machine insulation; partial discharges; stators; 0 to 16 kV; capacitance; harmonic analysis; laboratory stator mock-up; loss tangent; phase resolved partial discharge patterns; slot discharges; stator bars; Capacitance measurement; Harmonic analysis; Laboratories; Loss measurement; Paints; Partial discharge measurement; Partial discharges; Phase measurement; Stator bars; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 2002 Annual Report Conference on
Print_ISBN :
0-7803-7502-5
Type :
conf
DOI :
10.1109/CEIDP.2002.1048841
Filename :
1048841
Link To Document :
بازگشت