Abstract :
Adaptive spectral estimation techniques are known to provide good spectral resolution and contrast even when the observation window (OW) is very short. In this paper two adaptive techniques are tested and compared to the averaged periodogram (Welch) for blood velocity estimation. The blood power spectral capon (BPC) method is based on a standard minimum variance technique adapted to account for both averaging over slow-time and depth. The blood amplitude and phase estimation technique (BAPES) is based on finding a set of matched filters (one for each velocity component of interest) and filtering the blood process over slow-time and averaging over depth to find the power spectral density estimate. In this paper, the two adaptive methods are explained, and performance is assessed in controlled steady flow experiments and in-vivo measurements. The three methods were tested on a circulating flow rig with a blood mimicking fluid flowing in the tube. The scanning section is submerged in water to allow ultrasound data acquisition. Data was recorded using a BK8804 linear array transducer and the RASMUS ultrasound scanner. The controlled experiments showed that the OW could be significantly reduced when applying the adaptive methods without compromising spectral resolution or contrast. The in-vivo data was acquired using a BK8812 transducer. OWs of 128, 64, 32 and 16 slow- time samples were tested. Spectrograms with duration of 2 seconds were generated. Welch´s method required 128 samples to give a reasonable spectrogram, whereas the BPC only required 32 samples before the SNR became a limiting factor. The BAPES managed to display the spectrogram with sufficient quality at 16 slow-time samples.
Keywords :
biomedical ultrasonics; haemodynamics; rotational flow; RASMUS ultrasound scanner; Welch method; adaptive spectral estimation; adaptive techniques; blood amplitude and phase estimation technique; blood power spectral capon; blood velocity estimation; circulating flow; minimum variance technique; observation window; spectral velocity estimation; Adaptive control; Blood; Fluid flow control; Matched filters; Phase estimation; Programmable control; Spectrogram; Testing; Ultrasonic imaging; Ultrasonic transducers;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium, 2007. IEEE
Conference_Location :
New York, NY
ISSN :
1051-0117
Print_ISBN :
978-1-4244-1384-3
Electronic_ISBN :
1051-0117
Type :
conf
DOI :
10.1109/ULTSYM.2007.253
Filename :
4409826
Link To Document :
بازگشت