• DocumentCode
    2474880
  • Title

    Experience with dielectric diagnosis of high voltage motors in service

  • Author

    Rao, B. Nageshwar ; Mallikarjunappa, K. ; Keri, C.D. ; Moorching, S.N.

  • Author_Institution
    Central Power Res. Inst., Bangalore, India
  • fYear
    1993
  • fDate
    17-20 Oct 1993
  • Firstpage
    580
  • Lastpage
    585
  • Abstract
    Field testing and extensive laboratory investigations indicate that periodic diagnostic tests such as tan delta, capacitance, and IDE (integrated discharge energy) give useful information on the relative condition of winding insulation. Each test parameter provides particular information regarding the condition of stator insulation should be monitored and as many diagnostic parameters as possible should be monitored to obtain reliable and complete information regarding the state, quality, and trend in ageing of the insulation. A strong correlation has been shown to exist between tan delta and capacitance tip-ups
  • Keywords
    dielectric losses; electric breakdown; insulation testing; life testing; machine insulation; machine testing; stators; IDE; capacitance; capacitance tip-ups; dielectric diagnosis; high voltage motors; integrated discharge energy; periodic diagnostic tests; stator insulation; tan delta; winding insulation; Condition monitoring; Dielectric loss measurement; Dielectrics and electrical insulation; Inspection; Insulation testing; Maintenance; Stator windings; Synchronous motors; Thermal stresses; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena, 1993. Annual Report., Conference on
  • Conference_Location
    Pocono Manor, PA
  • Print_ISBN
    0-7803-0966-9
  • Type

    conf

  • DOI
    10.1109/CEIDP.1993.378910
  • Filename
    378910