Title :
Multi-factor ageing of stator coil insulation of HV machines and degree of correlation among non-destructive test parameters
Author :
Mallikarjunappa, K. ; Viswanatha, C. ; Moorching, S.N.
Author_Institution :
Central Power Res. Inst., Bangalore, India
Abstract :
Multifactor accelerated ageing studied have been carried out on scaled-down model coils of an 11-kV insulation system. The test parameters tan delta tip-up (δT), capacitance tip-up (ΔC/C), integrated discharge energy (IDE), and discharge inception voltage (Vi) were monitored at regular intervals during the ageing period to characterize the ageing processes. Attempts have been made to find the correlation between different test parameters as a function of ageing time. A good correlation is found to exist between δT and δC/C. The degree of correlation between different test parameters tends to increase as the ageing proceeds
Keywords :
ageing; insulation testing; insulator testing; life testing; stators; 11 kV; 11-kV insulation system; HV machines; ageing processes; capacitance tip-up; degree of correlation; discharge inception voltage; integrated discharge energy; multifactor accelerated ageing; stator coil insulation; tan delta tip-up; test parameters; Aging; Capacitance; Coils; Condition monitoring; Dielectrics and electrical insulation; Insulation testing; Nondestructive testing; Power system reliability; Stators; Thermal stresses;
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 1993. Annual Report., Conference on
Conference_Location :
Pocono Manor, PA
Print_ISBN :
0-7803-0966-9
DOI :
10.1109/CEIDP.1993.378913