DocumentCode :
2475327
Title :
Broadband noise parameter and S-parameter measurement technique
Author :
Schmatz, M.L. ; Baechtold, W.
Author_Institution :
Lab. for EM Fields & Microwave Electron., Eidgenossische Tech. Hochschule, Zurich, Switzerland
Volume :
3
fYear :
1997
fDate :
8-13 June 1997
Firstpage :
1443
Abstract :
An accurate noise parameter measurement technique is presented that uses an amplifier/attenuator noise source, a multi-octave tuner and a directional coupler for noise injection at all tuner states. The presented concept allows measurements with more than 30 different ENR steps and the ability to calibrate the ENR during system calibration. A system that demonstrates the concept was built for the frequency range from 0.5-6.0 GHz.
Keywords :
S-parameters; calibration; electric noise measurement; microwave measurement; 0.5 to 6.0 GHz; ENR; S-parameter; amplifier/attenuator noise source; broadband measurement; calibration; directional coupler; multi-octave tuner; noise injection; noise parameter; Broadband amplifiers; Directional couplers; Impedance; Measurement techniques; Noise figure; Noise generators; Noise measurement; Scattering parameters; Temperature; Tuners;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Symposium Digest, 1997., IEEE MTT-S International
Conference_Location :
Denver, CO, USA
ISSN :
0149-645X
Print_ISBN :
0-7803-3814-6
Type :
conf
DOI :
10.1109/MWSYM.1997.596601
Filename :
596601
Link To Document :