Title :
Measurement of internal inductance of capacitors by ramp pulse response technique
Author_Institution :
Central Power Res. Inst., India
Abstract :
Experiments were carried out to measure the internal inductance of a capacitor by the ramp pulse method. It is demonstrated that the minimum width of the excitation pulse should be at least 10 times larger than the Ri-Ct time constant. Care must be taken to minimize the extraneous signal pickup within the test circuit, and every lead must be as short as possible and shielded. It is also shown that suitable calibration should be carried out with noninductive resistors
Keywords :
calibration; capacitors; electron device testing; inductance measurement; Ri-Ct time constant; calibration; capacitors; excitation pulse; extraneous signal pickup; internal inductance; noninductive resistors; ramp pulse response technique; test circuit; Capacitors; Dielectric losses; Electrical resistance measurement; Equivalent circuits; Frequency measurement; HVDC transmission; Inductance measurement; Pulse measurements; Reservoirs; Voltage;
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 1993. Annual Report., Conference on
Conference_Location :
Pocono Manor, PA
Print_ISBN :
0-7803-0966-9
DOI :
10.1109/CEIDP.1993.378936