DocumentCode :
2475986
Title :
Autonomic nervous system driven cardiomyocytes in vitro
Author :
Takeuchi, Akimasa ; Mori, Masahide ; Kitagawa, Kana ; Shimba, Kenta ; Takayama, Yuzo ; Moriguchi, Hiroyuki ; Miwa, Keiko ; Kotani, Kiyoshi ; Lee, Jong-Kook ; Noshiro, Makoto ; Jimbo, Yasuhiko
Author_Institution :
Grad. Sch. of Frontier Sci., Univ. of Tokyo, Chiba, Japan
fYear :
2011
fDate :
Aug. 30 2011-Sept. 3 2011
Firstpage :
1945
Lastpage :
1948
Abstract :
Rat superior cervical ganglia (SCG), which are sympathetic ganglia, neurons and ventricular myocytes (VMs) were co-cultured separately in a minichamber placed on a microelectrode-array (MEA) substrate. The minichamber was fabricated photolithographically and had 2 compartments, 16 microcompartments and 8 microconduits. The SCG neurons were seeded into one of the compartments and all of the microcompartments using a glass pipette controlled by a micromanipulator and a microinjector. The VMs were seeded into the other compartment. Three days after seeding of the VMs, the neurites of the SCG neurons had connected with the VMs via the microconduits. Electrical stimulations, trains of biphasic square pulses, were applied to the SCG neurons in the microcompartments using 16 electrodes. Evoked responses were observed in several electrodes while electrical stimulation was applied to the SCG neurons. According to the two-way analysis of variance (ANOVA), the beat rate after electrical stimulation was affected by the frequency and the number of the stimulation pulses. These results suggest that pulse number and the frequency of the electrical stimulation contribute to modulation of the beat rate of the cardiomyocytes.
Keywords :
bioelectric phenomena; biomedical electrodes; cardiology; microelectrodes; microfabrication; micromanipulators; neurophysiology; photolithography; statistical analysis; ANOVA; SCG neurons; analysis of variance; autonomic nervous system; biphasic square pulse; electrical stimulation; evoked response; glass pipette; in-vitro cardiomyocytes; microcompartment; microconduits; microelectrode-array substrate; microinjector; micromanipulator; minichamber; neurites; photolithographically; rat superior cervical ganglia; sympathetic ganglia; ventricular myocytes; Analysis of variance; Educational institutions; Electrical stimulation; Electrodes; Neurons; Resonant frequency; Substrates; Animals; Autonomic Nervous System; Batch Cell Culture Techniques; Biological Clocks; Cell Communication; Cells, Cultured; Coculture Techniques; Equipment Design; Equipment Failure Analysis; Heart Rate; Microfluidic Analytical Techniques; Myocytes, Cardiac; Rats; Rats, Wistar; Superior Cervical Ganglion;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, EMBC, 2011 Annual International Conference of the IEEE
Conference_Location :
Boston, MA
ISSN :
1557-170X
Print_ISBN :
978-1-4244-4121-1
Electronic_ISBN :
1557-170X
Type :
conf
DOI :
10.1109/IEMBS.2011.6090549
Filename :
6090549
Link To Document :
بازگشت