DocumentCode :
2476072
Title :
Absolute distance measurement system using a coherent optical sensor
Author :
Norgia, Michele ; Magnani, Alessandro ; Pesatori, Alessandro
Author_Institution :
Dipt. di Elettron. e Inf., Politec. di Milano, Milan, Italy
fYear :
2012
fDate :
13-16 May 2012
Firstpage :
1362
Lastpage :
1365
Abstract :
This work describes the development of a new optical technique for absolute distance measurements, functioning in safety class 1. By current injection, a wavelength modulation takes place in the laser diode: using a particular algorithm to extract the frequency tone of the fringes induced by the self-mixing effect, it is possible to measure the absolute distance of a target, with a compact and low-cost device. By means of particular shaped pulses, the system can work in safety class 1.
Keywords :
distance measurement; optical sensors; optical variables measurement; semiconductor lasers; absolute distance measurement system; coherent optical sensor; laser diode; low-cost device; particular algorithm; self-mixing effect; shaped pulses; wavelength modulation; Current measurement; Frequency measurement; Measurement by laser beam; Modulation; Optical feedback; Optical interferometry; Optical variables measurement; Distance meausurements; Frequency measurement; Optical interferometry; Optoelectronic devices; Position measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Instrumentation and Measurement Technology Conference (I2MTC), 2012 IEEE International
Conference_Location :
Graz
ISSN :
1091-5281
Print_ISBN :
978-1-4577-1773-4
Type :
conf
DOI :
10.1109/I2MTC.2012.6229161
Filename :
6229161
Link To Document :
بازگشت