DocumentCode
2476102
Title
The frequency stability of the 50 Hz French railway
Author
Mariscotti, A. ; Slepicka, D.
Author_Institution
DYNATECH, Univ. of Genova, Genova, Italy
fYear
2012
fDate
13-16 May 2012
Firstpage
1406
Lastpage
1410
Abstract
The stability of the fundamental frequency of the Autotransformer 2 × 25 kV 50 Hz French railway is considered, compared also to that of 16.7 Hz systems, analyzed in a previous paper. Its influence on the processing of higher order harmonics is also evaluated. The stability is analyzed by means of the amplitude frequency spectrum, of the short-time Fourier transform and of the residuals of sine-wave fitting.
Keywords
autotransformers; fast Fourier transforms; frequency stability; railways; amplitude frequency spectrum; autotransformer; french railway; frequency 50 Hz; frequency stability; fundamental frequency; high order harmonics processing; short-time Fourier transform; sine-wave fitting; Circuit stability; Frequency estimation; Harmonic analysis; Power system stability; Rail transportation; Stability analysis; Time frequency analysis; Frequency stability; Guideway transportation systems; Power quality; Spectral analysis; Time domain analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Instrumentation and Measurement Technology Conference (I2MTC), 2012 IEEE International
Conference_Location
Graz
ISSN
1091-5281
Print_ISBN
978-1-4577-1773-4
Type
conf
DOI
10.1109/I2MTC.2012.6229163