Abstract :
This paper describes an implementation of volume rendering on a new parallel architectural system, the Hybrid System. The Hybrid System is a combination of a SIMD system with a MIMD system. For such an architecture, we have developed a new volume rendering algorithm called slice orientation. Using this new parallel architecture on the visualization algorithm, we have achieved speed-up rates more than its corresponding MIMD can achieve alone. In this paper, we also present a general formula for determining the speedup of the Hybrid System so that accurate predictions can be made on the performance of the Hybrid System
Keywords :
data visualisation; medical image processing; parallel algorithms; parallel architectures; performance evaluation; rendering (computer graphics); Hybrid System; MIMD system; SIMD system; medical image processing; parallel architecture; performance; slice orientation; speed-up; visualization algorithm; volume rendering; Biomedical image processing; Biomedical imaging; Casting; Concurrent computing; Data visualization; Electronic mail; Embedded system; Magnetic resonance imaging; Parallel architectures; Rendering (computer graphics);