DocumentCode
2476633
Title
Chronic cuff electrode recordings from walking Göttingen mini-pigs
Author
Andersen, Mads P. ; Munch, Majken ; Jensen, Winnie ; SØrensen, Preben ; Eder, Clemens F.
Author_Institution
Neurodan A/S, Aalborg, Denmark
fYear
2011
fDate
Aug. 30 2011-Sept. 3 2011
Firstpage
2280
Lastpage
2283
Abstract
We present data from cuff electrode recordings from a mixed sensory-/motor nerve as expressed during walking in chronically implanted Göttingen mini-pigs. Our results show that it is possible to filter out residual electromyographic interference and that the energy content of the resulting electroneurographic (ENG) signals modulate clearly with gait. The approach may be used to detect heel strike from cuff electrode measurements to control the timing of stimulation in implantable foot drop correction systems.
Keywords
biomedical electrodes; electromyography; gait analysis; medical signal detection; neurophysiology; ENG signals; chronic cuff electrode recordings; chronically implanted Gottingen minipigs; cuff electrode measurement; electromyographic interference; electroneurographic signal; energy content; gait cycle; heel strike; implantable foot drop correction system; mixed sensory-motor nerve; walking; Electrodes; Electromyography; Finite impulse response filter; Foot; Legged locomotion; Spectrogram; Action Potentials; Animals; Electrodes, Implanted; Equipment Design; Equipment Failure Analysis; Gait; Median Nerve; Monitoring, Ambulatory; Reproducibility of Results; Sensitivity and Specificity; Swine; Swine, Miniature; Walking;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, EMBC, 2011 Annual International Conference of the IEEE
Conference_Location
Boston, MA
ISSN
1557-170X
Print_ISBN
978-1-4244-4121-1
Electronic_ISBN
1557-170X
Type
conf
DOI
10.1109/IEMBS.2011.6090574
Filename
6090574
Link To Document