  • Title

    Analysis for adaptability of reducing LPG C2 content in absorbing-stabilizing system

  • Author

    Huang, Fenglin ; Qu, Xueli ; Tang, Xuan

  • Author_Institution
    Dept. of Energy & Power Eng., Xi´´an Jiaotong Univ., Xi´´an, China
  • fYear
    2011
  • fDate
    24-26 June 2011
  • Firstpage
    7380
  • Lastpage
    7384
  • Abstract
    According to the low yield of propylene existing in gas fractionation device due to higher C2 content in LPG, the factors affecting on LPG quality in the absorbing-stabilizing system were analyzed. Some technics such as optimization of operating condition and energy-efficient process were adopted to intensify the separation effect, offering the advice with lower C2 content (no more than 0.1 %χ) in LPG, fulfilling the technological requirements of double tower process for gas fractionation device.
  • Keywords
    petroleum; separation; C2; LPG quality; absorbing-stabilizing system; adaptability analysis; energy-efficient process; gas fractionation device; operating condition optimization; propylene; separation effect; Absorption; Chemical engineering; Chemical industry; FCC; Optimization; Petrochemicals; Petroleum; Absorbing-stabilizing; Absorption-desorption process; C2 content; LPG;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Remote Sensing, Environment and Transportation Engineering (RSETE), 2011 International Conference on
  • Conference_Location
    Nanjing
  • Print_ISBN
    978-1-4244-9172-8
  • Type

    conf

  • DOI
    10.1109/RSETE.2011.5966074
  • Filename
    5966074