• DocumentCode
    2479507
  • Title

    Results on the Power Quality of French and Italian 2×25 kV 50 Hz railways

  • Author

    Mariscotti, A.

  • Author_Institution
    DYNATECH, Univ. of Genova, Genova, Italy
  • fYear
    2012
  • fDate
    13-16 May 2012
  • Firstpage
    1400
  • Lastpage
    1405
  • Abstract
    The pantograph voltage and current waveforms recorded across the Italian and French high speed railway lines (both Autotransformer 2×25 kV 50 Hz systems) are analyzed to estimate some Power Quality indexes: harmonic spectra, harmonic distortion, displacement factor and fundamental component, in various load conditions. These indexes, that define the electrical interface between the rolling stock and the power supply, are all required by the technical standards for interoperability.
  • Keywords
    autotransformers; open systems; power supply quality; railways; French railways; Italian railways; autotransformer; current waveforms; displacement factor; electrical interface; frequency 50 Hz; fundamental component; harmonic distortion; harmonic spectra; high speed railway lines; interoperability; pantograph voltage; power quality; power supply; rolling stock; technical standards; voltage 25 kV; Harmonic analysis; Indexes; Power quality; Rail transportation; Standards; Transient analysis; Guideway transportation systems; Power quality; Spectral analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference (I2MTC), 2012 IEEE International
  • Conference_Location
    Graz
  • ISSN
    1091-5281
  • Print_ISBN
    978-1-4577-1773-4
  • Type

    conf

  • DOI
    10.1109/I2MTC.2012.6229341
  • Filename
    6229341