• DocumentCode
    2480032
  • Title

    Correction of the RF complex reflection coefficient using air-line impedance standards of arbitrary phase shift

  • Author

    Stumper, U.

  • Author_Institution
    Physikalisch Tech. Bundesanstalt, Braunschweig, Germany
  • fYear
    1996
  • fDate
    17-21 June 1996
  • Firstpage
    536
  • Lastpage
    537
  • Abstract
    If the method of correction of the complex reflection coefficient using air-line impedance standards is extended to arbitrary phase shifts, considerable deviations of the results from values obtained with the quarter-wave correction method may occur. The influence of various input quantities on the uncertainty of measurement has been investigated theoretically and experimentally.
  • Keywords
    electric impedance measurement; measurement standards; microwave reflectometry; RF complex reflection coefficient; air-line impedance standards; arbitrary phase shift; complex reflection coefficient; phase shift; quarter-wave correction method; uncertainty of measurement; Attenuation; Coaxial components; Connectors; Impedance; Length measurement; Measurement standards; Measurement uncertainty; Radio frequency; Reflection; System testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1996 Conference on
  • Conference_Location
    Braunschweig, Germany
  • Print_ISBN
    0-7803-3376-4
  • Type

    conf

  • DOI
    10.1109/CPEM.1996.547336
  • Filename
    547336