DocumentCode :
2480032
Title :
Correction of the RF complex reflection coefficient using air-line impedance standards of arbitrary phase shift
Author :
Stumper, U.
Author_Institution :
Physikalisch Tech. Bundesanstalt, Braunschweig, Germany
fYear :
1996
fDate :
17-21 June 1996
Firstpage :
536
Lastpage :
537
Abstract :
If the method of correction of the complex reflection coefficient using air-line impedance standards is extended to arbitrary phase shifts, considerable deviations of the results from values obtained with the quarter-wave correction method may occur. The influence of various input quantities on the uncertainty of measurement has been investigated theoretically and experimentally.
Keywords :
electric impedance measurement; measurement standards; microwave reflectometry; RF complex reflection coefficient; air-line impedance standards; arbitrary phase shift; complex reflection coefficient; phase shift; quarter-wave correction method; uncertainty of measurement; Attenuation; Coaxial components; Connectors; Impedance; Length measurement; Measurement standards; Measurement uncertainty; Radio frequency; Reflection; System testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements Digest, 1996 Conference on
Conference_Location :
Braunschweig, Germany
Print_ISBN :
0-7803-3376-4
Type :
conf
DOI :
10.1109/CPEM.1996.547336