DocumentCode :
24807
Title :
Recommendations for triboelectricity control in hospital environment
Author :
Wain, G.J.
Author_Institution :
Univ. Nac. de San Martin, Buenos Aires, Argentina
Volume :
11
Issue :
1
fYear :
2013
fDate :
Feb. 2013
Firstpage :
307
Lastpage :
313
Abstract :
This paper discuss associated problems with generation of triboelectric charges in the hospital environment, intrinsic damage happening and methods to mitigate associated risks derivate to this phenomenon.
Keywords :
biological effects of fields; hospitals; occupational safety; triboelectricity; associated risks; hospital environment; intrinsic damage; triboelectric charges; triboelectricity control; Electrostatic discharges; Gases; IEC standards; ISO standards; Silicon; Triboelectricity; Triboelectricity; conductive floor; electrostatic discharge; hospital safety;
fLanguage :
English
Journal_Title :
Latin America Transactions, IEEE (Revista IEEE America Latina)
Publisher :
ieee
ISSN :
1548-0992
Type :
jour
DOI :
10.1109/TLA.2013.6502821
Filename :
6502821
Link To Document :
بازگشت