The atomic hydrogen maser
Author
Ramsey, Norman F.
fYear
1962
fDate
25-27 April 1962
Firstpage
287
Lastpage
304
Abstract
Properties of the hydrogen maser and details of the apparatus will be discussed. 1beoretical expressions for noise and for the effects of various relaxation phenomena will be given, as well as expressions for effects, such as cavity pulling, which lead to frequency shifts in the maser. Experimental results on the comparison of two hydrogen masers will be presented and analyzed.
Keywords
Apertures; Atomic measurements; Doppler shift; Hydrogen; Masers; Microwave theory and techniques; Optical buffering; Radio frequency; Resonance; Signal to noise ratio;