• DocumentCode
    2483052
  • Title

    Applicability evaluation of the pneumatic gauging method for automotive fuel tanks

  • Author

    Brunnader, Rudolf ; Holler, Gert

  • Author_Institution
    Inst. of Electr. Meas. & Meas. Signal Process., Graz Univ. of Technol., Graz, Austria
  • fYear
    2012
  • fDate
    13-16 May 2012
  • Firstpage
    833
  • Lastpage
    838
  • Abstract
    As shown in previous papers, the pneumatic gauging method is applicable for both gas-tight and ventilated storage tanks. Therefore, the method can be used to detect the fill level of non-gas-tight tanks (e.g. fuel tanks). Based on a verified model, the paper demonstrates the applicability of the pneumatic gauging method to three different automotive fuel tanks. The experimental results are presented and a discussion of the results indicates constraints and potential improvements of the method.
  • Keywords
    fuel storage; fuel systems; gauges; tanks (containers); applicability evaluation; automotive fuel tanks; fill level detection; nongas-tight tanks; pneumatic gauging method; storage tanks; Acoustic measurements; Acoustics; Admittance; Admittance measurement; Equivalent circuits; Frequency measurement; Fuel storage; acoustic measurement method; fill-level sensing; pneumatic gauging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference (I2MTC), 2012 IEEE International
  • Conference_Location
    Graz
  • ISSN
    1091-5281
  • Print_ISBN
    978-1-4577-1773-4
  • Type

    conf

  • DOI
    10.1109/I2MTC.2012.6229536
  • Filename
    6229536