Title :
Absolute calibration of a 100 KV DC divider
Author_Institution :
Swedish Nat. Testing & Res. Inst., Boras, Sweden
Abstract :
An absolute determination of the ratio of a 100 kV DC divider has been made. A new Zener device that has recently become available has been used in a step-up mode to obtain the divider ratio. The uncertainty of the determination is 5.5 ppm.
Keywords :
Zener diodes; calibration; high-voltage techniques; voltage dividers; voltage measurement; 100 kV; DC divider; Zener device; absolute calibration; divider ratio; step-up mode; uncertainty; Calibration; Current measurement; Diodes; Dynamic voltage scaling; Laboratories; Low voltage; Performance evaluation; Strips; Testing; Voltage measurement;
Conference_Titel :
Precision Electromagnetic Measurements Digest, 1996 Conference on
Conference_Location :
Braunschweig, Germany
Print_ISBN :
0-7803-3376-4
DOI :
10.1109/CPEM.1996.547351