DocumentCode :
2484312
Title :
Dynamic response of variable frequency drives in electrical submersible pump systems
Author :
Liang, Xiaodong ; Ilochonwu, Obinna ; Adedun, Rotimi
Author_Institution :
Edmonton Product Center, Schlumberger, Edmonton, AB, Canada
fYear :
2012
fDate :
20-24 May 2012
Firstpage :
1
Lastpage :
11
Abstract :
Dynamic response of variable frequency drives (VFD) during short-circuit faults for the electrical submersible pump (ESP) systems are investigated in this paper. Because of special characteristics of VFDs and ESP systems, the dynamic response of the drive during faults is quite different from that of general power distribution systems. The simulation conducted by PSCAD provides detailed and clear pictures how the drive and the ESP motor will react for each specific fault.
Keywords :
dynamic response; induction motor drives; power distribution faults; pumps; short-circuit currents; variable speed drives; ESP motor; ESP systems; PSCAD simulation; VFD; dynamic response; electrical submersible pump motor systems; power distribution systems; short-circuit faults; two-pole three-phase induction motor; variable frequency drives; Inverters; PSCAD; TV; Dynamic response; short circuit fault; single-phased operation mode; variable frequency drives;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial & Commercial Power Systems Technical Conference (I&CPS), 2012 IEEE/IAS 48th
Conference_Location :
Louisville, KY
ISSN :
2158-4893
Print_ISBN :
978-1-4673-0652-2
Type :
conf
DOI :
10.1109/ICPS.2012.6229603
Filename :
6229603
Link To Document :
بازگشت