• DocumentCode
    2484361
  • Title

    Micropotentiometers as ac-dc transfer standards for low-voltage measurements

  • Author

    Schliestedt, G.

  • Author_Institution
    Physikalisch Tech. Bundesanstalt, Berlin, Germany
  • fYear
    1996
  • fDate
    17-21 June 1996
  • Firstpage
    574
  • Lastpage
    575
  • Abstract
    Micropotentiometers with commercial single-junction thermal converters and laboratory-made disk resistors are used at PTB as ac-dc voltage transfer standards at low voltages from 1 mV to 100 mV and frequencies from 10 Hz to 1 MHz. The measurement results and the estimated uncertainties are compared with those of other institutes at the international level.
  • Keywords
    calibration; measurement errors; measurement standards; potentiometers; thin film resistors; voltage measurement; 1 to 100 mV; 10 Hz to 1 MHz; AC-DC transfer standards; calibration; comparison measurements; double-bottom units; laboratory-made disk resistors; low-voltage measurements; micropotentiometers; optimum frequency response; reference standards; single-junction thermal converters; uncertainties; voltage transfer standards; Electrical resistance measurement; Flanges; Frequency measurement; Impedance; Measurement standards; Nickel alloys; Resistors; Speech synthesis; Thermal resistance; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1996 Conference on
  • Conference_Location
    Braunschweig, Germany
  • Print_ISBN
    0-7803-3376-4
  • Type

    conf

  • DOI
    10.1109/CPEM.1996.547356
  • Filename
    547356