• DocumentCode
    2485539
  • Title

    Maximum levels inside an electromagnetic shielded cavity

  • Author

    Höijer, Magnus

  • Author_Institution
    Inf. Syst., Swedish Defence Res. Agency FOI, Linköping, Sweden
  • fYear
    2010
  • fDate
    25-30 July 2010
  • Firstpage
    143
  • Lastpage
    146
  • Abstract
    We present analytic expressions to quickly calculate the maximum electric field and power levels inside an electromagnetic shielded cavity. Typical maximum values are 9-11 dB larger than the corresponding average values. The method is applicable to both worst case estimates in e.g. an avionics bay, as well as to calculate the test quantity when performing a radiated susceptibility test in the reverberation chamber.
  • Keywords
    electric fields; electromagnetic shielding; reverberation chambers; electric field; electromagnetic shielded cavity; power level; radiated susceptibility test; reverberation chamber; Cavity resonators; Electric fields; Random variables; Reverberation chamber; Uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility (EMC), 2010 IEEE International Symposium on
  • Conference_Location
    Fort Lauderdale, FL
  • ISSN
    2158-110X
  • Print_ISBN
    978-1-4244-6305-3
  • Type

    conf

  • DOI
    10.1109/ISEMC.2010.5711261
  • Filename
    5711261