DocumentCode :
2485668
Title :
Determination of the time-constants of thermoelectric effects in thermal converters using a fast-reversed DC
Author :
Sasaki, H. ; Inglis, B.D. ; Takahashi, K. ; Klonz, M.
Author_Institution :
Electron. Metrol. Sect., Electrotech. Lab., Tsukuba, Japan
fYear :
1996
fDate :
17-21 June 1996
Firstpage :
588
Lastpage :
589
Abstract :
A formula for determining the time-constants of thermoelectric effects in thermal converters from FRDC-DC transfer difference measurements versus reversing frequency is derived. The influence of higher-frequency harmonics in the FRDC-waveform is calculated for shunt capacitances in the heater/range-resistor combination.
Keywords :
convertors; electric current measurement; measurement standards; thermoelectricity; voltage measurement; fast-reversed DC; heater/range-resistor combination; higher-frequency harmonics; modelling; reversing frequency; shunt capacitances; thermal converters; thermoelectric effects; time-constants; Capacitance; Circuits; Curve fitting; Frequency measurement; Laboratories; Mathematical model; Metrology; Steady-state; Thermoelectricity; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements Digest, 1996 Conference on
Conference_Location :
Braunschweig, Germany
Print_ISBN :
0-7803-3376-4
Type :
conf
DOI :
10.1109/CPEM.1996.547363
Filename :
547363
Link To Document :
بازگشت