  • Title

    Characterization of the bulk current injection calibration-jig for probe-model extraction

  • Author

    Grassi, Flavia ; Pignari, Sergio A.

  • Author_Institution
    Dipt. di Elettrotec., Politec. di Milano, Vinci, Italy
  • fYear
    2010
  • fDate
    25-30 July 2010
  • Firstpage
    344
  • Lastpage
    347
  • Abstract
    In this paper, a circuit model of the jig used for calibration of bulk current injection (BCI) probes is derived. The jig model is used to develop a procedure for probe-model extraction, based on measurement data, with the injection device mounted onto the calibration jig. This allows to exploit a device, i.e., the calibration jig, belonging to standard equipment of every EMC laboratory, and provides precise indications on how to adapt the probe parameters to the characteristics of the actual wiring harness to be tested.
  • Keywords
    calibration; electromagnetic compatibility; fixtures; EMC laboratory; bulk current injection calibration; calibration jig; injection device; probe-model extraction; Adaptation model; Calibration; Conductors; Frequency measurement; Impedance; Integrated circuit modeling; Probes;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility (EMC), 2010 IEEE International Symposium on
  • Conference_Location
    Fort Lauderdale, FL
  • ISSN
    2158-110X
  • Print_ISBN
    978-1-4244-6305-3
  • Type

    conf

  • DOI
    10.1109/ISEMC.2010.5711298
  • Filename
    5711298