DocumentCode
2486281
Title
Characterization of the bulk current injection calibration-jig for probe-model extraction
Author
Grassi, Flavia ; Pignari, Sergio A.
Author_Institution
Dipt. di Elettrotec., Politec. di Milano, Vinci, Italy
fYear
2010
fDate
25-30 July 2010
Firstpage
344
Lastpage
347
Abstract
In this paper, a circuit model of the jig used for calibration of bulk current injection (BCI) probes is derived. The jig model is used to develop a procedure for probe-model extraction, based on measurement data, with the injection device mounted onto the calibration jig. This allows to exploit a device, i.e., the calibration jig, belonging to standard equipment of every EMC laboratory, and provides precise indications on how to adapt the probe parameters to the characteristics of the actual wiring harness to be tested.
Keywords
calibration; electromagnetic compatibility; fixtures; EMC laboratory; bulk current injection calibration; calibration jig; injection device; probe-model extraction; Adaptation model; Calibration; Conductors; Frequency measurement; Impedance; Integrated circuit modeling; Probes;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility (EMC), 2010 IEEE International Symposium on
Conference_Location
Fort Lauderdale, FL
ISSN
2158-110X
Print_ISBN
978-1-4244-6305-3
Type
conf
DOI
10.1109/ISEMC.2010.5711298
Filename
5711298
Link To Document