• DocumentCode
    2487190
  • Title

    Three-probe reflectometer error analysis

  • Author

    Hrabar, S. ; Babic, N. ; Balachandran, W.

  • Author_Institution
    Dept. of Manuf. & Eng. Syst., Brunel Univ., Uxbridge, UK
  • fYear
    1996
  • fDate
    17-21 June 1996
  • Firstpage
    604
  • Lastpage
    605
  • Abstract
    The reflection coefficient measurement error for a three-probe reflectometer was analyzed. The influence of power measurement error, probe location, reference coupler directivity, attenuator value and probe coupling on the reflectometer´s useful frequency bandwidth was investigated using computer simulation. The useful frequency bandwidth for the reflectometer with commonly used parameters, was estimated.
  • Keywords
    S-parameters; calibration; directional couplers; measurement errors; microwave reflectometry; multiport networks; network analysers; power measurement; reflectometers; attenuator value; calibration matrix; capacitive coupling; computer simulation; phase errors; power measurement error; probe coupling; probe location; reference coupler directivity; reflection coefficient measurement error; scattering matrix; six-port error analysis; three-probe reflectometer; useful frequency bandwidth; Attenuators; Bandwidth; Computer errors; Computer simulation; Error analysis; Frequency estimation; Measurement errors; Power measurement; Probes; Reflection;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1996 Conference on
  • Conference_Location
    Braunschweig, Germany
  • Print_ISBN
    0-7803-3376-4
  • Type

    conf

  • DOI
    10.1109/CPEM.1996.547371
  • Filename
    547371