• DocumentCode
    2487687
  • Title

    Comparison of measured and computed near and far fields of a Heatsink using the Feature Selective Validation (FSV) method

  • Author

    Bhobe, Alpesh ; Sochoux, Philippe

  • fYear
    2010
  • fDate
    25-30 July 2010
  • Firstpage
    732
  • Lastpage
    736
  • Abstract
    In this paper we outline the comparison of far field electric field of a Heatsink using the Frequency Selective Validation (FSV) method. Numerical simulations are performed using 3D-EM tools like Ansoft HFSS and CST Microstripes. The FSV method has been used to compare the data between the two different numerical approaches as well as with the measured data. Though the E-field data shows a good agreement between measurement and simulations, the FSV data analysis proves a poor to good agreement to measurements.
  • Keywords
    heat sinks; numerical analysis; 3D-EM tools; Ansoft HFSS; CST Micros; far electric field; feature selective validation method; heatsink; near electric field; numerical simulations; Antenna measurements; Frequency division multiplexing; Frequency measurement; Heat sinks; Heating; Microstrip; Numerical models; FSVEMC; Feature Selective Validation; Heatsink; IEEE 1597.1;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility (EMC), 2010 IEEE International Symposium on
  • Conference_Location
    Fort Lauderdale, FL
  • ISSN
    2158-110X
  • Print_ISBN
    978-1-4244-6305-3
  • Type

    conf

  • DOI
    10.1109/ISEMC.2010.5711369
  • Filename
    5711369