DocumentCode :
2494514
Title :
Comparison of competing designs for delay-short calibration standards at WR-1.5
Author :
Arsenovic, A.I. ; Weikle, R.M.
Author_Institution :
Charles L. Brown Dept. of Electr. & Comput. Eng., Univ. of Virginia, Charlottesville, VA, USA
fYear :
2012
fDate :
23-28 Sept. 2012
Firstpage :
1
Lastpage :
2
Abstract :
Two competing delay-short calibration standard designs for WM-380/WR-1.5 rectangular waveguide (500-750GHz) are evaluated. Quantitative estimates of the connector uncertainty are made and it is shown that an end-milled design out-performs the shim design. The effect of each standard´s repeatability on calibration uncertainty is used to determine corrected measurement uncertainty for an eighth wavelength verification standard.
Keywords :
calibration; measurement uncertainty; rectangular waveguides; WM-380-WR-1.5 rectangular waveguide; connector uncertainty; corrected measurement uncertainty; delay-short calibration standard design; end-milled design; frequency 500 GHz to 750 GHz; shim design; wavelength verification standard; Calibration; Delay; Measurement uncertainty; Phase measurement; Rectangular waveguides; Standards; Uncertainty;