    ARX model of human thumb flexor muscle dynamics applicable to synthesis of myoelectric hand

  • Author

    Akazawa, K. ; Takano, S. ; Shiraki, T. ; Okuno, R.

  • Author_Institution
    Graduate Sch. of Inf. Sci. & Technol., Osaka Univ., Japan
  • Volume
    3
  • fYear
    2002
  • fDate
    23-26 Oct. 2002
  • Abstract
    The purpose of this study was to identify dynamics of flexor pollicis longus (FPL) muscle including short latency stretch reflex for synthesis of a myoelectric hand. First, force response to ramp stretch was measured with varying isometric force. Then a third order ARX (autoregressive with exogenous input) model, was used to express the force response. Determined ARX model was also expressed with a transfer function.
  • Keywords
    artificial limbs; biomechanics; electromyography; physiological models; ARX model; autoregressive with exogenous input model; force response; human thumb flexor muscle dynamics; myoelectric hand synthesis; ramp stretch; short latency stretch reflex; transfer function; varying isometric force; Delay; Elasticity; Force measurement; Humans; Information science; Muscles; Parameter estimation; Thumb; Transfer functions; Viscosity;