Title :
The calculation of the maximum relative time interval error on a synchronization interfaces
Author :
Savchuk, O.V. ; Shaposhnikov, V.N.
Author_Institution :
´´WIRCOM´´ Ltd. Soc., Kiev, Ukraine
Abstract :
The maximum time interval error (MTIE) is one of the main time domain stability measures for the signals on a SDH transport network synchronization interface. A method for synchronization signal stability measurement on the primary reference clock (PRC) interface is considered.
Keywords :
stability; synchronisation; synchronous digital hierarchy; MTIE; PRC interface; SDH transport network; maximum time interval error; primary reference clock interface; signal stability measurement; synchronization interface; time domain stability; Global Positioning System; Helium; IEEE catalog; Partial response channels; Roentgenium; Sun; Telecommunications;
Conference_Titel :
Microwave and Telecommunication Technology, 2004. CriMico 2004. 2004 14th International Crimean Conference on
Print_ISBN :
966-7968-69-3
DOI :
10.1109/CRMICO.2004.183202