DocumentCode
2495822
Title
A fast radial offset surface-tracking model for simulation of patella-femoral articulation
Author
Andersen, Clark R. ; Buford, William L., Jr.
Author_Institution
Orthopaedic Biomech. Lab., Univ. of Texas Med. Branch, Galveston, TX, USA
Volume
3
fYear
2002
fDate
23-26 Oct. 2002
Firstpage
2527
Abstract
A surface-tracking model of the motion of the patella with respect to the femur is introduced. The model involves a radial translation of the patella as a function of angle, based upon a sine fit to the precalculated offsets between the articulating surfaces which result from rotation of the patella about a fixed axis.
Keywords
biomechanics; kinematics; orthopaedics; physiological models; rotation; articulating surfaces; fast radial offset surface-tracking model; femur; patella-femoral articulation simulation; precalculated offsets; radial translation; rotation about fixed axis; sine fit; Biomechanics; Cadaver; Computational modeling; Computed tomography; Kinematics; Knee; Laboratories; Medical simulation; Orthopedic surgery; Surface fitting;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology, 2002. 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society EMBS/BMES Conference, 2002. Proceedings of the Second Joint
ISSN
1094-687X
Print_ISBN
0-7803-7612-9
Type
conf
DOI
10.1109/IEMBS.2002.1053409
Filename
1053409