DocumentCode
2496657
Title
Virtual experiments for controlling blood glucose level in type I diabetes
Author
Agar, Baris ; Birol, Gulnur ; Cinar, Ali
Author_Institution
Dept. of Chem. & Environ. Eng., Illinois Inst. of Technol., Chicago, IL, USA
Volume
3
fYear
2002
fDate
23-26 Oct. 2002
Firstpage
2609
Abstract
An educational software (GLUCOSIM) is developed for illustrating the dynamics of blood glucose and insulin levels in Type I diabetes patients. This work extends the use or GLUCOSIM to closed-loop control of blood glucose levels with the use of an implantable glucose sensor and an insulin infusion pump. Various control strategies are applied to maintain blood glucose concentration close to natural values (Euglycemia) in Type I diabetic patients.
Keywords
biochemistry; biocontrol; biomedical education; biomedical transducers; blood; diseases; drug delivery systems; medical computing; medical control systems; organic compounds; physiological models; Euglycemia; GLUCOSIM; blood glucose concentration; blood glucose dynamics; blood glucose level control; closed-loop control; control strategies; diabetic patients; educational software; implantable glucose sensor; insulin infusion pump; insulin level dynamics; type I diabetes; Biological system modeling; Blood; Chemical technology; Diabetes; Differential equations; Humans; Insulin; Mathematical model; Sugar; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology, 2002. 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society EMBS/BMES Conference, 2002. Proceedings of the Second Joint
ISSN
1094-687X
Print_ISBN
0-7803-7612-9
Type
conf
DOI
10.1109/IEMBS.2002.1053451