DocumentCode
2496934
Title
Verifying the performance of transparent clocks in PTP systems
Author
Burch, Jeff ; Green, Kenneth ; Nakulski, John ; Vook, Dieter
Author_Institution
Meas. Res. Lab., Agilent Technol., Santa Clara, CA, USA
fYear
2009
fDate
12-16 Oct. 2009
Firstpage
1
Lastpage
6
Abstract
This paper presents test results from several IEEE1588 Transparent Clocks (TC) under realistic network conditions. Imperfections are documented that may impact the end-to-end synchronization performance between Master Clocks (MC) and Slave Clocks (SC). To help service providers select and configure these devices to meet their synchronization performance needs, a new test methodology for characterizing TC performance under real-world conditions is presented. The ldquoCorrection Factor Errorrdquo test method is introduced which could serve as the basis for future IEEE1588 test standards for these devices.
Keywords
IEEE standards; clocks; synchronisation; IEEE1588 test standards; IEEE1588 transparent clocks; PTP systems; correction factor error test method; end-to-end synchronization performance; master clocks; slave clocks; Clocks; Degradation; Delay; Master-slave; Multicast protocols; Routing protocols; Switches; Synchronization; System testing; Telecommunication traffic; IEEE1588; Measurement Methodology; Performance; Test System; Transparent Clock;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Clock Synchronization for Measurement, Control and Communication, 2009. ISPCS 2009. International Symposium on
Conference_Location
Brescia
Print_ISBN
978-1-4244-4391-8
Electronic_ISBN
978-1-4244-4392-5
Type
conf
DOI
10.1109/ISPCS.2009.5340195
Filename
5340195
Link To Document