• DocumentCode
    2497297
  • Title

    A Semi-Cylindrical Capacitive Sensor with Signal Conditioner for Flow Meter Applications

  • Author

    Chiang, Cheng-Ta ; Huang, Yu-Chung

  • Author_Institution
    Nat. Chiao Tung Univ., Hsing Chu
  • fYear
    2006
  • fDate
    22-25 Oct. 2006
  • Firstpage
    1139
  • Lastpage
    1142
  • Abstract
    In this paper, a semi-cylindrical capacitive sensor with signal conditioner for flow meter applications is newly proposed. The numerical analysis method to calculate the capacitance of the semi-cylindrical capacitive sensor is analyzed and discussed. The pF-range capacitive variation of the semi-cylindrical capacitive sensor can be detected and converted into voltage variation by the signal conditioner. Besides, the signal conditioner is compact to simplify the circuit complexity, and could be easily implemented for flow meter applications. All the functions of the signal conditioner for flow meter applications are tested and proved through HSPICE simulation. Measurement results have successfully confirmed the correct functions and performance of the semi-cylindrical capacitive sensor with signal conditioner for flow meter applications, which ranges from 0.136 to 4.746 L/min, on the LCD panel coating machine.
  • Keywords
    capacitive sensors; flowmeters; signal processing equipment; HSPICE simulation; LCD panel coating machine; flow meter applications; numerical analysis method; pF-range capacitive variation; semi-cylindrical capacitive sensor; signal conditioner; voltage variation; Capacitance; Capacitive sensors; Circuit simulation; Circuit testing; Coatings; Complexity theory; Dielectrics; Fluid flow measurement; Numerical analysis; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Sensors, 2006. 5th IEEE Conference on
  • Conference_Location
    Daegu
  • ISSN
    1930-0395
  • Print_ISBN
    1-4244-0375-8
  • Electronic_ISBN
    1930-0395
  • Type

    conf

  • DOI
    10.1109/ICSENS.2007.355827
  • Filename
    4178822