    Magnetostriction assessment of power transformer (a case study of 30/40MVA, 132/33 kV transformer at Bauchi substation)

  • Author

    Yusuf, Ahmad ; Amoo, Abdullahi ; Aliyu, Usman ; Mustafa, Mohd Wazir ; Zin, Abdullah Asuhaimi Mohd

  • Author_Institution
    Electr. Dept., Fed. Polytech., Bauchi, Nigeria
  • fYear
    2012
  • fDate
    6-7 June 2012
  • Firstpage
    114
  • Lastpage
    118
  • Abstract
    A lot of things determine the life expectancy of a transformer such as overheating due to triplen harmonics, unbalanced loading, vibro-acoustic noise and so on. For this reason, this paper presents the investigation carried out on the magnetostrictive sound of Bauchi, 30/40 MVA, 132/33 KV substation transformer. Readings were taken using standard audio recording instrument for various loading and voltage conditions in the mornings, afternoons and nights for six days and the offline assessment was carried out using digital spectrum analyzer. However, no access could be gained to the variation of certain important parameters, like changing of core dimensions, loosing or tightening of core and so on, for the substation transformer in-situ in the substation hence separate laboratory test transformers were used in the assessment of the effect of core damping pressure, construction looseness and transformer saturation on the vibro-acoustic noise. Conclusively, increasing the operation voltage of transformer tends to produce more magnetostriction effect while loosening core lamination increases the energy losses.
  • Keywords
    laminations; magnetostriction; power transformer testing; substations; transformer cores; audio recording instrument; construction looseness; core damping pressure; core dimensions; core lamination; digital spectrum analyzer; laboratory test transformers; life expectancy; magnetostriction assessment; offline assessment; power transformer; substation transformer; transformer saturation; triplen harmonics; vibroacoustic noise; voltage 132 kV; voltage 33 kV; Circuit faults; Hysteresis; Magnetoacoustic effects; Magnetostriction; Power transformers; Transformer cores; Bloch-walls; Digital spectrum analyzer; Magnetostriction; NEMA method; Power transformer;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Engineering and Optimization Conference (PEDCO) Melaka, Malaysia, 2012 Ieee International
  • Conference_Location
    Melaka
  • Print_ISBN
    978-1-4673-0660-7
  • Type

    conf

  • DOI
    10.1109/PEOCO.2012.6230845
  • Filename
    6230845