• DocumentCode
    2499251
  • Title

    Designing of blower motors on mining trucks

  • Author

    Mirzaei, S. ; Perugini, D.L.

  • Author_Institution
    Unit Rig- Min. Truck, Caterpillar Global Min., South Milwaukee, WI, USA
  • fYear
    2012
  • fDate
    6-7 June 2012
  • Firstpage
    242
  • Lastpage
    245
  • Abstract
    This paper summarized key points to design blower motors for cooling alternator and traction motors on mining trucks. The both blower motors are directly connected to the alternator terminals, which have widely variable voltage and frequency. Although the alternator voltage is a sinusoidal wave form, but a huge rectifier, as a non-linear load, destroys the voltage wave form. New blowers were designed with VPI insulation, insulated bearings and large frame to protect Spike and transient voltage, shaft currents, and harmonic heating.
  • Keywords
    alternators; road vehicles; shafts; traction motors; Spike; VPI insulation; blower motors designing; cooling alternator; harmonic heating; mining trucks; non-linear load; shaft currents; traction motors; transient voltage; Alternators; Induction motors; Insulation; Inverters; Shafts; Torque; Traction motors; NEMA; TEFC; Traction Motors; VFD; VPI;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Engineering and Optimization Conference (PEDCO) Melaka, Malaysia, 2012 Ieee International
  • Conference_Location
    Melaka
  • Print_ISBN
    978-1-4673-0660-7
  • Type

    conf

  • DOI
    10.1109/PEOCO.2012.6230868
  • Filename
    6230868