Title :
Evaluation and assessment of transformer failure on 132kV substation
Author :
Ariff, M. H Mohammed ; Kadir, M. Z A Ab ; Jasni, J. ; Mesron, R. ; Salahuddin, M.T. ; Lamsi, J.
Author_Institution :
Dept. of Electr. & Electron. Eng., Univ. Putra Malaysia, Serdang
Abstract :
Insulation coordination models are an essential part of power system studies and are used to determine the expected overhead line back-flashover rate. A study is carried out to investigate and evaluate the effect of lightning stresses on the 132 kV substation in the way to improve its reliability in the event of active lightning activities. This paper also presents the modeling guidelines on substation for this transient analysis in order to evaluate the performance and to recommend such configuration to optimize its design to be not only to withstand the stresses but to be more cost effective. The modeling and simulation are carried out using one of the most powerful power system simulations tools that is PSCAD-EMTDC and the substation layout design is adapted from 132/11 kV Simpang Renggam-Ayer Hitam substation, courtesy of Tenaga Nasional Berhad, Malaysia (TNB). The model is based on single phase line model as it is suggested by the IEEE to be adequate to represent the substation in transient analysis simulation. The outcome of this paper will be the results of lightning stresses in term of voltage level measured at particular points in substation. The results are then compared with the suggested basic lightning insulation level (BIL) for assessment of transformer failure.
Keywords :
failure analysis; flashover; insulation co-ordination; insulation testing; lightning; power overhead lines; power system reliability; power transformer insulation; power transformer testing; substation insulation; transient analysis; voltage measurement; BIL; PSCAD-EMTDC; Simpang Renggam-Ayer Hitam substation; TNB; basic lightning insulation level; insulation coordination model; lightning stress; overhead line back-flashover rate; power system simulation; single-phase line model; substation layout design; substation reliability; transformer failure evaluation; transient analysis; voltage 11 kV; voltage 132 kV; voltage level measurement; Guidelines; Lightning; PSCAD; Power system modeling; Power system reliability; Power system simulation; Power transformer insulation; Stress; Substations; Transient analysis; Insulation Coordination; Lightning; PSCAD; Substation Modeling; Transformer;
Conference_Titel :
Power and Energy Conference, 2008. PECon 2008. IEEE 2nd International
Conference_Location :
Johor Bahru
Print_ISBN :
978-1-4244-2404-7
Electronic_ISBN :
978-1-4244-2405-4
DOI :
10.1109/PECON.2008.4762439