Abstract :
In this paper, time evolution of PD patterns and phase-dependence of waveforms of PD current pulses were measured by a computer system and a phase-angle gate control technique respectively, when the artificial defects were separately placed at the EPR/XLPE interfaces with or without silicone oil. As a result, PD patterns and current pulse-waveforms obviously differed depending on the types of defects and aging duration. Moreover, rise time tr of PD current pulses varied slightly with aging time for each kind of defect. The variations of these PD characteristics have clearly indicated the transition of PD mechanisms and treeing due to the progressive degradation of XLPE insulation. An attempt was also made to interpret the results and interfacial effects of the simulated XLPE cable joint
Keywords :
XLPE insulation; ageing; insulation testing; partial discharge measurement; power cable insulation; power cable testing; trees (electrical); aging; current pulse-waveforms; defects; insulation degradation; interfacial phenomena; partial discharge; phase-angle gate control technique; rise time; silicone oil; simulated XLPE cable joint; treeing; Aging; Computer interfaces; Control systems; Current measurement; Paramagnetic resonance; Partial discharge measurement; Partial discharges; Phase measurement; Pulse measurements; Time measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulating Materials, 1998. Proceedings of 1998 International Symposium on
Conference_Location :
Toyohashi
Print_ISBN :
4-88686-050-8
Type :
conf
DOI :
10.1109/ISEIM.1998.741791
Filename :
741791
Link To Document :
بازگشت